Scale labels
Read the EAN-13 labels with weight or price printed by your scale at the register.
If your scale prints barcode labels, TPVStream reads them at the register. You weigh at the counter and charge with the scanner, without typing the weight again.
Turn on labels
- Open Settings › Scale & Weighing.
- Turn on Scale labels.
- Enter the prefixes your scale uses: Weight prefix (grams) and Price prefix (cents). The defaults are 21 and 22. They must be between 20 and 29 and different.
Label format
These are EAN-13 codes in this format: PP LLLLL VVVVV C
| Part | Meaning |
|---|---|
| PP | Prefix |
| LLLLL | Product PLU |
| VVVVV | Weight in grams or price in cents |
| C | Check digit |
Prepare the products
The PLU must match the SKU or the code of a product sold by weight. The product can't have variations or modifiers.
Keep the same price per kg on the scale and the POS. If they differ, a label with a price is refused.
If a label isn't read
| Message | What to do |
|---|---|
| PLU has no weighed product | Put that PLU in the product's SKU or code |
| PLU used by several products | Keep the PLU on one product only |
| Remove variations and modifiers | Take them off the product |
| Price/kg does not match the label | Set the same price on the scale and the POS |