Printers and hardware

Scale labels

Read the EAN-13 labels with weight or price printed by your scale at the register.

On this page

If your scale prints barcode labels, TPVStream reads them at the register. You weigh at the counter and charge with the scanner, without typing the weight again.

Turn on labels

  1. Open Settings › Scale & Weighing.
  2. Turn on Scale labels.
  3. Enter the prefixes your scale uses: Weight prefix (grams) and Price prefix (cents). The defaults are 21 and 22. They must be between 20 and 29 and different.

Label format

These are EAN-13 codes in this format: PP LLLLL VVVVV C

Part Meaning
PP Prefix
LLLLL Product PLU
VVVVV Weight in grams or price in cents
C Check digit

Prepare the products

The PLU must match the SKU or the code of a product sold by weight. The product can't have variations or modifiers.

Keep the same price per kg on the scale and the POS. If they differ, a label with a price is refused.

If a label isn't read

Message What to do
PLU has no weighed product Put that PLU in the product's SKU or code
PLU used by several products Keep the PLU on one product only
Remove variations and modifiers Take them off the product
Price/kg does not match the label Set the same price on the scale and the POS
WhatsApp